Refresher Training
More Information +
Method of delivery
Combination of theory and skills tasks (1 day onsite)
Units of Competency
UETDREL006 – Work safely in the vicinity of live electrical apparatus as a non-electrical worker
HLTAID009 – Provide cardiopulmonary resuscitation
UETDRMP010 (Previously UETDRRF007) – Provide First Aid in an ESI Environment
UETDRMP007 (Previously UETDRRF004) – Perform Rescue from a Live Low Voltage Panel
UETDRMP006 (Previously UETDRRF003) – Perform pole top rescue
UETDRMP005 (Previously UETDRRF002) – Perform EWP rescue
UETDRMP004 (Previously UETTDRRF08) – Perform EWP controlled descent escape
UETDRMP011 (Previously UETTDRRF11) Testing of connections to Low Voltage electricity networks
UETDRMP002 (Previously UETTDRRF01) – ESI safety rules for work on, near or in the vicinity of electrical apparatus (Essential Energy)
Certification Training
Endeavour Safety Rules
Essential Energy Safety Rules
Entry Requirement
The initial training for the units of competency that need to be refreshed.
More Information +
Trade assistant, Apprentice, Telecommunications worker
Method of delivery
Combination of theory and skills tasks (1 day onsite)
Some online learning is required prior to attending. This ensures the on-site part of the training is utilised more effectively.
Units of Competency
UETDREL006 – Work safely in the vicinity of live electrical apparatus as a non-electrical worker
HLTAID009 – Provide cardiopulmonary resuscitation
UETDRMP010 (Previously UETDRRF007) – Provide First Aid in an ESI Environment
UETDRMP007 (Previously UETDRRF004) – Perform Rescue from a Live Low Voltage Panel
UETDRMP002 (Previously UETTDRRF01) – ESI safety rules for work on, near or in the vicinity of electrical apparatus
Certification Training
Endeavour Safety Rules
Essential Energy Safety Rules
Optional for Overhead Workers (Extra $130)
UETDRMP006 (Previously UETDRRF003) – Perform pole top rescue
UETDRMP005 (Previously UETDRRF002) – Perform EWP rescue
UETDRMP004 (Previously UETTDRRF08) – Perform EWP controlled descent escape
Entry Requirement
The initial training for the units of competency that need to be refreshed.
Electrical Supply Industry New Worker
More Information +
HLTAID009 – Provide cardiopulmonary resuscitation
UETDRMP010 (Previously UETDRRF007) – Provide First Aid in an ESI Environment
UETDRMP007 (Previously UETDRRF004) – Perform Rescue from a Live Low Voltage Panel
Electrical Supply Industry New Worker
(With Overhead Work)
$785 (GST Exempt)
2 Days
More Information +
Telecommunications Workers (Class1Xf),
Units mandatory for all Level 1 ASPs
UETDREL006 – Work safely in the vicinity of live electrical apparatus as a non-electrical worker OR UETDREL005 – Work safely in the vicinity of live electrical apparatus (For those who are electrically qualified)
HLTAID009 – Provide cardiopulmonary resuscitation
UETDRMP010 (Previously UETDRRF007) – Provide First Aid in an ESI Environment
UETDRMP007 (Previously UETDRRF004) – Perform Rescue from a Live Low Voltage Panel
If working in the vicinity of overhead mains (eg Vegetation Worker)
UETDRMP006 (Previously UETDRRF003) – Perform pole top rescue
UETDRMP005 (Previously UETDRRF002) – Perform elevated work platform rescue
UETDRMP004 (Previously UETTDRRF08) – Perform elevated work platform controlled descent escape
Entry Requirement
Nil
More Information +
Delivery Method
Online
Units of Competency
UETDRMP002 (Previously UETTDRRF01) – ESI safety rules for work on, near or in the vicinity of electrical apparatus
Entry Requirement
Nil
Level 1 ASP and Cable Jointing
More Information +
Units of Competency
UETDRMP011 (Previously UETTDRRF11) Testing of connections to Low Voltage electricity networks
Entry Requirement
Qualified Lineworker
Additional Requirements
To meet the distributor requirements (Ausgrid, Essential, Endeavour) the ‘Electrical Supply Industry New Worker’ units on this page must also be completed.
More Information +
UETDREL001 – Apply environmental requirements
UETDREL005 – Work safely in the vicinity of live electrical apparatus
UETDRDU016 – Lay power cables
UETDRDU015 – Joint, terminate and maintain low voltage underground polymeric cable
UETDRDU013 – Joint, terminate and maintain high voltage underground polymeric cable
Entry Requirement
Certificate III in Electrotechnology Electrician OR Distribution Cable Jointing OR Distribution Overhead
Additional Requirements
To meet the NSW ASP scheme requirements the ‘UETDRMP011 (Previously UETTDRRF11) Testing of connections to Low Voltage electricity networks’ must be completed.
To meet the distributor requirements (Ausgrid, Essential, Endeavour) the ‘Electrical Supply Industry New Worker’ units on this page must also be completed.
More Information +
UETDRDU019 – Transition joint high voltage paper insulated cable to high voltage polymeric cable
Entry Requirement
Electrical licence in any Australian State or Territory (Electrician Pathway)
The Class 1C polymeric cable jointer course listed on this page.
Additional Requirements
To meet the distributor requirements (Ausgrid, Essential, Endeavour) the ‘Electrical Supply Industry New Worker’ units on this page must also be completed.
Level 2 ASP
More Information +
Required by Ausgrid, Endeavour and Essential Energy
Units of Competency (All Network Distributors)
HLTAID009 – Provide cardiopulmonary resuscitation
UETDRMP010 (Previously UETDRRF007) – Provide First Aid in an ESI Environment
UETDRMP007 (Previously UETDRRF004) – Perform Rescue from a Live Low Voltage Panel
Entry Requirement
Nil
More Information +
Units of Competency
UETDRIS011 – Install and maintain low voltage underground services
Entry Requirement
The mandatory units listed on this page
More Information +
Units of Competency
UEEEL0078 – Install and commission whole current electricity meters **
**Class 2D does not authorise ASPs to install meters. Please refer to the ASP Scheme FAQs
Entry Requirement
Electrical license in any Australian State or Territory
Note regarding requirements
To meet requirements of Class 2D in the NSW ASP scheme rules, the statutory and mandatory units need only be completed – refer to Table 4 here
However, to apply for authorisation with a metering provider you must comply with the current legislation and this code (Clause 9.3) – which requires completion of UEEEL0078.
INSTRUCTIONS
STEP 1
You must complete Statutory and Core training before Underground and/or Overhead training.
Register in Statutory training and leave comment letting us know the other sessions you want to register in. We’ll do the rest of the booking for you.
STEP 2
Apply for accreditation with the Department of Industry. The contact details are at the bottom of this page.
STEP 3
Apply for authorisation with the electrical distributors who’s area you wish to work in. You’ll also need to enrol in their electrical safety rules training. The contact details are at the bottom of this page.
Ausgrid – Sydney, Central Coast, Newcastle and Hunter region
Endeavour – Sydney Greater West, Wollongong and Illawarra
Essential Energy – The rest of NSW
CONTACT
02 9188 4424
122 Hume Highway, Chullora 2190
Due to unprecedented demand our phone lines are always busy. For the quickest response please use the contact form on our contact us page.
METHOD OF DELIVERY
Combination of theory and skills tasks
NUMERACY CHECK
To check your numeracy skills are at the required level for this course, test yourself by completing our numeracy questionnaire HERE
AWARD
Accredited – Statement of Attainment
Helpful Contacts And Information
.
DEPARTMENT OF INDUSTRY
Departments website with more information is available HERE.
Click HERE to download the NSW Department of Industry ASP Scheme Rules
(02) 8275 1960
Email: [email protected]
ENDEAVOUR ENERGY AUTHORISATIONS
Click HERE for Endeavour Energy’s Level 2 ASP Authorisations Manual.
ASP training requirements are listed in section 6.11
Email: authorisations@ endeavourenergy.com.au
ENDEAVOUR ENERGY TRAINING
(02) 9853 7530
Email: technical.training@ endeavourenergy.com.au
Sydney: Joadja Road, Hoxton Park
AUSGRID AUTHORISATIONS
Click HERE for Ausgrid’s Electrical Supply Standards on ASPs (ES4).
Email: [email protected]
AUSGRID TRAINING
View Ausgrid’s training requirements HERE
(02) 8745 1561
Email: [email protected]
Sydney: 48 Holker Street, Silverwater
Newcastle: 78 Abbott Street, Wallsend
ESSENTIAL ENERGY AUTHORISATIONS
Click HERE for Essential Energy’s Authorisation Requirements
Email: [email protected]
ESSENTIAL ENERGY TRAINING
View Essential Energy’s Training matrix HERE
(02) 6588 4570
Email: [email protected]
Port Macquarie: 8 Buller Street, Port Macquarie